Szczegóły Produktu
Miejsce pochodzenia: Chiny
Nazwa handlowa: Macylab
Orzecznictwo: ROSH, FCC, CE, ISO9001
Numer modelu: ICP-6800S
Warunki płatności i wysyłki
Minimalne zamówienie: 1 szt
Cena: $32775
Szczegóły pakowania: pojemnik
Czas dostawy: 15 dzień roboczy
Zasady płatności: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Możliwość Supply: 1000szt
Name: |
Macylab High Quality ICP OES Inductively Coupled Plasma Emission Spectrometer ICP-6800S Used For Oil Detection |
Keyword: |
Inductively Coupled Plasma Emission Spectrometer |
Circuit type: |
Solid-state Rf Power Supply, With Function Of Automatch |
Frequency: |
27.12MHz±0.05% |
Power Output: |
800W—1200W |
Power Output Stability: |
<0.3% |
Escaped RF radiation: |
30cm Away From The Instrument, |
Electric Field: |
E<2V/m |
Name: |
Macylab High Quality ICP OES Inductively Coupled Plasma Emission Spectrometer ICP-6800S Used For Oil Detection |
Keyword: |
Inductively Coupled Plasma Emission Spectrometer |
Circuit type: |
Solid-state Rf Power Supply, With Function Of Automatch |
Frequency: |
27.12MHz±0.05% |
Power Output: |
800W—1200W |
Power Output Stability: |
<0.3% |
Escaped RF radiation: |
30cm Away From The Instrument, |
Electric Field: |
E<2V/m |
Macylab Wysokiej jakości spektrometr emisji plazmy ICP OES indukcyjnie połączony ICP-6800S stosowany do wykrywania ropy naftowej
Parametry techniczne
Parametry techniczne RFPower | |
Rodzaj obwodu | zasilacz prądu RF w stanie stałym, z funkcją automatycznego |
Częstotliwość | 270,12 MHz±0,05% |
Stabilność częstotliwości | < 0,1% |
Wydajność mocy | 800W-1200W |
Stabilność mocy wyjściowej | < 0,3% |
Ucieczka promieniowania RF | 30 cm od przyrządu, pole elektryczne: E<2V/m |
Parametry techniczne systemu pobierania próbek | |
Średnica wewnętrzna cewki roboczej wyjściowej | 25 mm |
Rurka momentu obrotowego | Trzy koncentryczne, zewnętrzna średnica 20 mm |
Nebulizator koaksjalny | Średnica zewnętrzna 6 mm |
Komora atomująca z podwójnym beczkiem | Średnica zewnętrzna 34 mm |
Kontrola przepływu gazu | |
Argonometr przepływu plazmy | (100-1000) l/h (1,6-16 l/min) |
Pomiar przepływu argonu pomocniczy | (10-100) l/h (0,16-1,66 l/min) |
Przepływomierz argonu nośnego | (10-100) l/h (0,16-1,66 l/min) |
Zawór utrzymujący ciśnienie | (0-0,4 MPa) |
Woda chłodząca:temperatura | 20-25oC, przepływ>5L/min, ciśnienie hydrauliczne>0,1MPa |
Spektrometr | |
Optyka | Typ Czerny-Turner |
Długość ogniskowa | 1000 mm |
Szczotkowanie | Ogrzewanie holograficzne wiązki jonowej, 3600L/mm lub 2400L/mm |
Wzajemne rozproszenie liniowe | 00,26 nm/mm |
Rozstrzygnięcie | ≤ 0,007nm (3600 linii sieci);≤0,015nm (2400 linii sieci) |
Elementy | WL(nm) | Ograniczenie | Elementy | WL(nm) | Ograniczenie | |
- Co to jest? | 408.672 | < 3.0 | Kr | 267.716 | < 5.0 | |
C | 413.765 | < 5.0 | Al. | 396.152 | < 5.0 | |
Pr | 414.311 | < 5.0 | Zr | 343.823 | < 5.0 | |
Z | 401.225 | < 5.0 | Ag | 328.068 | < 3.0 | |
Sm | 360.946 | < 10.0 | Sr. | 407.771 | < 1.0 | |
UE | 381.967 | < 1.0 | O | 242.795 | < 5.0 | |
Gd | 342.247 | < 10.0 | Pt | 265.945 | < 5.0 | |
Tb | 350.917 | < 3.0 | Pd | 340.458 | < 5.0 | |
Dy | 353.170 | < 3.0 | Nie. | 224.268 | < 10.0 | |
Ho. | 345.600 | < 3.0 | Rh | 343.489 | < 10.0 | |
- Nie. | 337.271 | < 3.0 | Ru | 240.272 | < 5.0 | |
Tm | 313.126 | < 3.0 | Ba | 455.403 | < 1.0 | |
Yb | 369.419 | < 1.0 | Jak | 228.812 | ≤ 15 | |
Lu. | 261.541 | < 3.0 | Sb | 206.833 | ≤ 15 | |
Y | 371.030 | < 1.0 | Bi | 223.061 | ≤ 10 | |
Sc | 335.373 | < 1.0 | Hg | 253.652 | ≤ 15 | |
Ta | 226.230 | < 5.0 | Pb | 220.353 | ≤ 15 | |
Nb | 313.340 | < 5.0 | - Nie. | 294.364 | ≤ 10 | |
Mn | 257.610 | < 3.0 | Wymagania | 203.985 | ≤ 10 | |
Mg | 279.553 | < 1.0 | Sł | 242.949 | ≤ 20 | |
B | 249.773 | < 10.0 | Te | 214.281 | ≤ 10 | |
Zn | 213.856 | < 3.0 | Ta | 226.230 | ≤ 5.0 | |
Co | 228.616 | < 3.0 | /Trzecia | 283.730 | ≤ 10 | |
Tak. | 251.611 | < 10.0 | TK | 276.787 | ≤ 30 | |
Ni | 232.003 | < 5.0 | Re | 227.525 | ≤ 5 | |
Cd | 226.502 | < 3.0 | Ge | 209.426 | ≤ 15 | |
Fe | 239.562 | < 3.0 | Os | 225.585 | ≤ 1 | |
Ca. | 393.366 | < 1.0 | W | 207.911 | ≤ 10 | |
Mo. | 281.615 | < 5.0 | Cu | 324.754 | < 3.0 | |
V | 310.230 | < 5.0 | Li | 670.784 | ≤ 3 | |
Bądź | 313.041 | < 1.0 | Nie. | 588.995 | ≤ 20 | |
Ty | 334.941 | < 3.0 | K | 766.490 | ≤ 60 |
Nasza fabryka
Założona w Szanghaju w 2012 roku firma Macylab Instruments Inc. posiada trzy zakłady badawczo-rozwojowe.(badania i rozwój)i bazy produkcyjne w Szanghaju, Pekinie i Jiangsu, oraz trzy spółki zależne w całości posiadane. Głównymi produktami firmy są ultrafioletowy widzialny spektrofotometr, spektrometr absorpcji atomowej,fotometr fluorescencji atomowej, ICP-AES/ICP-MS, spektrometr emisji plazmy o sprzężeniu indukcyjnym, ultra mikrospektrophotometr
Częste pytania
Q1: Dlaczego wybrać Macy Lab?
P2: Czy jesteś fabryką czy firmą handlową?
A2: Jesteśmy profesjonalnym producentem UV/Vis Wyroby z materiałów objętych pozycją 8541 lub 8542 Spektrofotometr Absorpcji AtomowejMamy trzy bazy badawczo-rozwojowe i produkcyjne w Szanghaju, Pekinie i Jiangsu.oraz trzy spółki zależne będące w całości własnością.
Q3: OEM, ODM akceptowalne czy nie?
A3: Zdecydowanie.
P4: Ile mogę dostać za cenę?
A4: Zazwyczaj cytujemy w ciągu 12 godzin po otrzymaniu zapytania
P5: Jakie są twoje Warunki dostawy?
A5: Akceptujemy FOB, EXW, CFR. Możesz wybrać ten, który jest dla Ciebie najbardziej wygodny lub ekonomiczny.
P6: A co z obsługą posprzedażną?
A6: Naszezużyte materiały do spektrofotometrów są w pełni wyposażone, system obsługi posprzedażowej jest dobry oraz jeden- rok gwarancji, co może rozwiązać problemy klienta.
Możemy zapewnić naszym klientom zakup części w ciągu 5 lat, a aktualizacje i wymiana produktów nie będą miały wpływu.
A co z MOQ?
Zazwyczaj nie'Nie mamy MOQ, możemy zaoferować nawet tylko 1 jednostkę, podczas gdy, można zamówić hurtowo, i jesteśmy bardzo zadowoleni, aby zaoferować dużą zniżkę.
P8: Zamówienie próbki jest w porządku?
Odpowiedź: Zamówienie próbki nie stanowi problemu.
P9: Co?'Czy klient może wybrać rodzaj przesyłki?
A9: Zwykle wysyłamy drogą morską lub lotniczą.
Możemy również zapewnić rozsądne rozwiązania zgodnie z Twoimi wymaganiami transportowymi.
P10: Czy możecie zaoferować certyfikację jakości?
A10: Oczywiście. Mamy wszelkiego rodzaju certyfikaty, takie jak certyfikat CE UE, certyfikat ROHS UE, certyfikat FDA USA, certyfikat CQO i certyfikat systemu zarządzania jakością ISO9001;certyfikacja systemu ochrony środowiska ISO 14001; certyfikacja systemu zdrowia zawodowego ISO 45001; certyfikacja FCC itp.